Guangzhou Shice Equipment Co., Ltd.

Quality is our life.

Manufacturer from China
Active Member
5 Years
Home / Products / Light Testing Equipment /

Ground Recessed Luminaires Led Testing Equipment

Contact Now
Guangzhou Shice Equipment Co., Ltd.
City:guangzhou
Country/Region:china
Contact Person:MsLucy
Contact Now

Ground Recessed Luminaires Led Testing Equipment

Ask Latest Price
Video Channel
Brand Name :SHC
Model Number :SC-GRE
Certification :CNAS、TUV、ITS、CSA、BV、SGS (cost additional)
Place of Origin :China
MOQ :1 unit
Price :USD 1000-5000 piece
Payment Terms :T/T, Western Union, MoneyGram, D/A
Supply Ability :999 units per month
Delivery Time :in 15 work days
Packaging Details :Carton
Standard :IEC 60598-2-13 Clause 13.6.1, 13.6.2
Customize :OEM, ODM
Controller :Mitsubishi PLC
Display :touch screen
Station :1 station
Test object :ground accessed luminaires
Test :static load test and torque test
Max. load :20KN
Rubber punch :diameter 50mm, thickness 50mm
Maintain time :5-10s for torque test, 1min for static load test
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

IEC60598-2-13 Ground Recessed Luminaires Light Testing Equipment ​

Main technical parameters:

Power supply 380V 50Hz
Test object ground accessed luminaires
Test static load test and torque test
Max. load 20KN
Rubber punch diameter 50mm, thickness 50mm
Maintain time 5-10s for torque test, 1min for static load test
Station 1 station
Standard IEC 60598-2-13 Clause 13.6.1, 13.6.2
Control Mitsubishi PLC
Display Touch screen

Production introduction:

This test equipment conforms to IEC 60598-2-13 clause 13.6.1 and clause 13.6.2 standard requirements.

It is used for the ground accessed luminaires static load test and torque test.

This equipment is controlled by PLC electrical system, the whole operation is controlled on the touch screen, all the parameters can be preset on the touch screen, include every selection mode of the kettle, the touch screen with the functions of manual operation, automatic operation and real-time display.

IEC 60598-2-13

13.6.1 Resistance to static load

Luminaires shall withstand the minimum static load according to the manufacturer's instruction.

13.6.2 Resistance too torque and shear loads
Luminaires designed to be used in areas where motor vehicles may circulate, carriageways, parking areas, etc.

shall withstand the forces exerted by a turning, breaking or accelerating tire.

Test details please reference to standard discription.

Ground Recessed Luminaires Led Testing Equipment

Inquiry Cart 0